A maintenance plan sets out which tasks are done on which equipment, how often and by whom, and how they are documented. Creating one takes seven steps: inventory the equipment, list the tasks, set the frequency, assign responsibilities, schedule the work, decide how to document it, and review the plan regularly.
Whether it's your own facility's equipment or your customers', a maintenance plan is the difference between you running the work and breakdowns running you.
A good maintenance plan aims for as much preventive work and as little corrective work as possible.
Make a list of all the equipment to be maintained, with model, serial number and site. If you don't have one yet, start here: the article on equipment tracking explains what data to record.
For each equipment model, gather the maintenance tasks: cleaning, inspection, measurement, part replacement. The primary source is the manufacturer's manual; also check whether any code or regulation applies to the equipment. If you record tasks per model, you don't have to list them again for every single unit.
Frequency is set primarily by the manufacturer's requirements and applicable codes, along with the equipment's age and how heavily it's used. Where there's no requirement, decide based on service history and past breakdowns, then refine it with experience.
Decide who does each task: your own technician, which crew, or a subcontractor. Check whether it fits your team's capacity, especially during seasonal peaks. Our article on capacity planning gives you pointers.
Routine maintenance is best set up as recurring jobs: monthly, every six months, yearly, or, for example, on the first Monday of every month. If you can, put them in quieter months so you have capacity for repairs during the peak season.
Every maintenance visit should have a service report that goes into the equipment's service history. That way you can always trace what happened to a unit, and at the next maintenance the technician sees the history. You'll find the fields of a maintenance service report below, with a template.
A maintenance plan isn't a one-time document. Review it at least once a year: which equipment failed despite maintenance, where could you space visits out or bring them closer together, and does the plan still fit your team's capacity?
The table below is only an example of how a plan is structured. Always set tasks and frequency based on the manufacturer's requirements and applicable codes.
| Equipment | Task | Frequency | Responsible |
|---|---|---|---|
| Ductless mini-split, indoor unit | filter cleaning, disinfection | every 6 months | Crew 1 |
| Ductless mini-split, outdoor unit | coil cleaning, pressure check | yearly | Crew 1 |
| Gas boiler | annual service, combustion analysis | yearly | Crew 2 |
| Heat pump | filter change, connection check | yearly | Crew 2 |
| Solar inverter | visual inspection, error log check | yearly | Subcontractor |
| Field | Example |
|---|---|
| Equipment | Daikin 2MXS18 outdoor unit, serial number: SN-123456 |
| Customer and site | Sample Corp., 1200 Main Street, Austin, TX 78701, mechanical room |
| Work performed | ✓ filter cleaning, ✓ coil cleaning, ✓ pressure check |
| Readings | operating pressure: 142 psi |
| Parts replaced | none |
| Labor time | 9:00–10:30 am |
| Photos | 4, before and after |
| Next maintenance | November 2027 |
| Signature | Sarah Miller, office manager |
We cover the general fields of a service report in detail in this article.
Kompozit's capacity report shows the week's maintenance per technician at a glance, and marks in red when someone is booked in two places at once.
You'll find industry examples on our pages for HVAC-R, plumbing and heating and facility management. For examples tailored to elevators, fire and security systems, and gates, see our pages on elevator maintenance, fire and security and gates and barriers.
If you'd like to see how your maintenance plan would work in Kompozit, request a free demo.
A maintenance plan sets out which maintenance tasks are done on which equipment, how often and by whom, and how they are documented. Its goal is that no maintenance is missed, breakdowns become rarer and work can be planned ahead.
Frequency is set primarily by the manufacturer's requirements, along with legal obligations, the equipment's age and how heavily it's used. Where the manufacturer gives no guidance, set it based on past breakdowns and service history, then refine it with experience.
Preventive maintenance is scheduled, regular work that prevents breakdowns, such as replacing filters or an annual inspection. Corrective maintenance happens once something has already failed. A good maintenance plan aims to make as much of the work preventive as possible.
A maintenance service report should include the equipment model and serial number, the site, a checklist of tasks performed, readings, parts replaced, labor time, photos, the recommended date of the next maintenance and the customer's signature.
In field service software, maintenance can be set up as a recurring job, for example monthly, every six months, yearly, or on the first Monday of every month. Kompozit creates the next job automatically and emails a weekly list of due maintenance, so none is missed.